মঙ্গলবার, ২৩ এপ্রিল, ২০১৩

Team deploys hundreds of tiny untethered surgical tools in first animal biopsies

Team deploys hundreds of tiny untethered surgical tools in first animal biopsies [ Back to EurekAlert! ] Public release date: 23-Apr-2013
[ | E-mail | Share Share ]

Contact: Phil Sneiderman
prs@jhu.edu
443-287-9960
Johns Hopkins University

By using swarms of untethered grippers, each as small as a speck of dust, Johns Hopkins engineers and physicians say they have devised a new way to perform biopsies that could provide a more effective way to access narrow conduits in the body as well as find early signs of cancer or other diseases.

In two recent peer-reviewed journal articles, the team reported successful animal testing of the tiny tools, which require no batteries, wires or tethers as they seize internal tissue samples. The devices are called "mu-grippers," incorporating the Greek letter that represents the term for "micro." Instead of relying on electric or pneumatic power, these star-shaped tools are autonomously activated by the body's heat, which causes their tiny "fingers" to close on clusters of cells. Because the tools also contain a magnetic material, they can be retrieved through an existing body opening via a magnetic catheter.

In the April print edition of Gastroenterology, the researchers described their use of the mu-grippers to collect cells from the colon and esophagus of a pig, which was selected because its intestinal tract is similar to that of humans. Earlier this year, the team members reported in the journal Advanced Materials that they had successfully inserted the mu-grippers through the mouth and stomach of a live animal and released them in a hard-to-access place, the bile duct, from which they obtained tissue samples.

"This is the first time that anyone has used a sub-millimeter-sized device -- the size of a dust particle -- to conduct a biopsy in a live animal," said David Gracias, an associate professor of chemical and biomolecular engineering whose lab team developed the microgrippers. "That's a significant accomplishment. And because we can send the grippers in through natural orifices, it is an important advance in minimally invasive treatment and a step toward the ultimate goal of making surgical procedures noninvasive."

Another member of the research team, physician Florin M. Selaru of the Johns Hopkins School of Medicine, said the mu-grippers could lead to an entirely new approach to conducting biopsies, which are considered the "gold standard" test for diagnosing cancer and other diseases.

The advantage of the mu-grippers, he said, is that they could collect far more samples from many more locations. He pointed out that the much larger forceps used during a typical colonoscopy may remove 30 to 40 pieces of tissue to be studied for signs of cancer. But despite a doctor's best intentions, the small number of specimens makes it easy to miss diseased lesions.

"What's the likelihood of finding the needle in the haystack?" said Selaru, an assistant professor in the Division of Gastroenterology and Hepatology. "Based on a small sample, you can't always draw accurate inferences. We need to be able to do a larger statistical sampling of the tissue. That's what would give us enough statistical power to draw a conclusion, which, in essence, is what we're trying to do with the microgrippers. We could deploy hundreds or even thousands of these grippers to get more samples and a better idea of what kind of or whether a disease is present."

Although each mu-gripper can grab a much smaller tissue sample than larger biopsy tools, the researchers said each gripper can retrieve enough cells for effective microscopic inspection and genetic analysis. Armed with this information, they said, the patient's physician could be better prepared to diagnose and treat the patient.

This approach would be possible through the latest application of the Gracias lab's self-assembling tiny surgical tools, which can be activated by heat or chemicals, without relying on electrical wires, tubes, batteries or tethers. The low-cost devices are fabricated through photolithography, the same process used to make computer chips. Their fingerlike projections are made of materials that would normally curl inward, but the team adds a polymer resin to give the joints rigidity and to keep the digits from closing.

Prior to a biopsy, the grippers are kept on ice, so that the fingers remain in this extended position. An endoscopy tool then is used to insert hundreds of grippers into the area targeted for a biopsy. Within about five minutes, the warmth of the body causes the polymer coating to soften, and the fingers curl inward to grasp some tissue. A magnetic tool is then inserted to retrieve them.

Although the animal testing results are promising, the researchers said the process will require further refinement before human testing can begin. "The next step is improving how we deploy the grippers," Selaru said. "The concept is sound, but we still need to address some of the details. The other thing we need to do is thorough safety studies."

Further development can be costly, however. The team has applied for grants to fund advances in the project, which is protected by provisional patents obtained through the Johns Hopkins Technology Transfer Office. Biotechnology investors might also help move the project forward.

"It is more a question of money than time as to how long it will take before we could use this in human patients," Selaru said

###

Along with Gracias and Selaru, the Johns Hopkins researchers who contributed significantly to the two journal articles were Evin Gultepe, Sumitaka Yamanaka, Eun Shin and Anthony Kalloo. Additional contributors were Kate E. Laflin, Sachin Kadam, Yoosun Shim, Alexandru V. Olaru, Berkeley Limketkai, Mouen A. Khashab and Jatinder S. Randhawa. The researchers are affiliated with School of Medicine, the Whiting School of Engineering and the Johns Hopkins Institute for NanoBioTechnology.

Funding for this research has come from the National Institutes of Health, the National Science Foundation, the Flight Attendants Medical Research Institute and the Broad Medical Research Institute.

Related links:

Gracias Lab: http://www.jhu.edu/chembe/gracias/
Division of Gastroenterology and Hepatology: http://www.hopkinsmedicine.org/gastroenterology_hepatology
Whiting School of Engineering: http://engineering.jhu.edu
School of Medicine: http://www.hopkinsmedicine.org/som/
Institute for NanoBioTechnology: http://inbt.jhu.edu/

THE JOHNS HOPKINS UNIVERSITY
OFFICE OF NEWS AND INFORMATION
Suite 540, 901 S. Bond St.
Baltimore, Maryland 21231

Media Contact:

Phil Sneiderman
Cell: 410-299-7462


[ Back to EurekAlert! ] [ | E-mail | Share Share ]

?


AAAS and EurekAlert! are not responsible for the accuracy of news releases posted to EurekAlert! by contributing institutions or for the use of any information through the EurekAlert! system.


Team deploys hundreds of tiny untethered surgical tools in first animal biopsies [ Back to EurekAlert! ] Public release date: 23-Apr-2013
[ | E-mail | Share Share ]

Contact: Phil Sneiderman
prs@jhu.edu
443-287-9960
Johns Hopkins University

By using swarms of untethered grippers, each as small as a speck of dust, Johns Hopkins engineers and physicians say they have devised a new way to perform biopsies that could provide a more effective way to access narrow conduits in the body as well as find early signs of cancer or other diseases.

In two recent peer-reviewed journal articles, the team reported successful animal testing of the tiny tools, which require no batteries, wires or tethers as they seize internal tissue samples. The devices are called "mu-grippers," incorporating the Greek letter that represents the term for "micro." Instead of relying on electric or pneumatic power, these star-shaped tools are autonomously activated by the body's heat, which causes their tiny "fingers" to close on clusters of cells. Because the tools also contain a magnetic material, they can be retrieved through an existing body opening via a magnetic catheter.

In the April print edition of Gastroenterology, the researchers described their use of the mu-grippers to collect cells from the colon and esophagus of a pig, which was selected because its intestinal tract is similar to that of humans. Earlier this year, the team members reported in the journal Advanced Materials that they had successfully inserted the mu-grippers through the mouth and stomach of a live animal and released them in a hard-to-access place, the bile duct, from which they obtained tissue samples.

"This is the first time that anyone has used a sub-millimeter-sized device -- the size of a dust particle -- to conduct a biopsy in a live animal," said David Gracias, an associate professor of chemical and biomolecular engineering whose lab team developed the microgrippers. "That's a significant accomplishment. And because we can send the grippers in through natural orifices, it is an important advance in minimally invasive treatment and a step toward the ultimate goal of making surgical procedures noninvasive."

Another member of the research team, physician Florin M. Selaru of the Johns Hopkins School of Medicine, said the mu-grippers could lead to an entirely new approach to conducting biopsies, which are considered the "gold standard" test for diagnosing cancer and other diseases.

The advantage of the mu-grippers, he said, is that they could collect far more samples from many more locations. He pointed out that the much larger forceps used during a typical colonoscopy may remove 30 to 40 pieces of tissue to be studied for signs of cancer. But despite a doctor's best intentions, the small number of specimens makes it easy to miss diseased lesions.

"What's the likelihood of finding the needle in the haystack?" said Selaru, an assistant professor in the Division of Gastroenterology and Hepatology. "Based on a small sample, you can't always draw accurate inferences. We need to be able to do a larger statistical sampling of the tissue. That's what would give us enough statistical power to draw a conclusion, which, in essence, is what we're trying to do with the microgrippers. We could deploy hundreds or even thousands of these grippers to get more samples and a better idea of what kind of or whether a disease is present."

Although each mu-gripper can grab a much smaller tissue sample than larger biopsy tools, the researchers said each gripper can retrieve enough cells for effective microscopic inspection and genetic analysis. Armed with this information, they said, the patient's physician could be better prepared to diagnose and treat the patient.

This approach would be possible through the latest application of the Gracias lab's self-assembling tiny surgical tools, which can be activated by heat or chemicals, without relying on electrical wires, tubes, batteries or tethers. The low-cost devices are fabricated through photolithography, the same process used to make computer chips. Their fingerlike projections are made of materials that would normally curl inward, but the team adds a polymer resin to give the joints rigidity and to keep the digits from closing.

Prior to a biopsy, the grippers are kept on ice, so that the fingers remain in this extended position. An endoscopy tool then is used to insert hundreds of grippers into the area targeted for a biopsy. Within about five minutes, the warmth of the body causes the polymer coating to soften, and the fingers curl inward to grasp some tissue. A magnetic tool is then inserted to retrieve them.

Although the animal testing results are promising, the researchers said the process will require further refinement before human testing can begin. "The next step is improving how we deploy the grippers," Selaru said. "The concept is sound, but we still need to address some of the details. The other thing we need to do is thorough safety studies."

Further development can be costly, however. The team has applied for grants to fund advances in the project, which is protected by provisional patents obtained through the Johns Hopkins Technology Transfer Office. Biotechnology investors might also help move the project forward.

"It is more a question of money than time as to how long it will take before we could use this in human patients," Selaru said

###

Along with Gracias and Selaru, the Johns Hopkins researchers who contributed significantly to the two journal articles were Evin Gultepe, Sumitaka Yamanaka, Eun Shin and Anthony Kalloo. Additional contributors were Kate E. Laflin, Sachin Kadam, Yoosun Shim, Alexandru V. Olaru, Berkeley Limketkai, Mouen A. Khashab and Jatinder S. Randhawa. The researchers are affiliated with School of Medicine, the Whiting School of Engineering and the Johns Hopkins Institute for NanoBioTechnology.

Funding for this research has come from the National Institutes of Health, the National Science Foundation, the Flight Attendants Medical Research Institute and the Broad Medical Research Institute.

Related links:

Gracias Lab: http://www.jhu.edu/chembe/gracias/
Division of Gastroenterology and Hepatology: http://www.hopkinsmedicine.org/gastroenterology_hepatology
Whiting School of Engineering: http://engineering.jhu.edu
School of Medicine: http://www.hopkinsmedicine.org/som/
Institute for NanoBioTechnology: http://inbt.jhu.edu/

THE JOHNS HOPKINS UNIVERSITY
OFFICE OF NEWS AND INFORMATION
Suite 540, 901 S. Bond St.
Baltimore, Maryland 21231

Media Contact:

Phil Sneiderman
Cell: 410-299-7462


[ Back to EurekAlert! ] [ | E-mail | Share Share ]

?


AAAS and EurekAlert! are not responsible for the accuracy of news releases posted to EurekAlert! by contributing institutions or for the use of any information through the EurekAlert! system.


Source: http://www.eurekalert.org/pub_releases/2013-04/jhu-tdh042313.php

chauncey billups caucus results exton kurt warner kurt warner ricky williams missouri primary

কোন মন্তব্য নেই:

একটি মন্তব্য পোস্ট করুন